KB-018: Packet drop alerts from NIC RX ring overflows¶
Symptom¶
CephNodeNetworkPacketDrops fires for a Kubernetes node on bond0 and
enp1s0f0, then resolves within minutes. The rule has no for: and uses a
1-minute rate, so a single burst of 10 or more drops per second fires it.
Cause¶
The X520 ports (ixgbe) drop frames when their RX ring is full. ethtool -S
enp1s0f0 shows every drop as rx_missed_errors, while rx_dropped,
rx_no_dma_resources and the softnet drop counters stay at zero. The ring
was at the 512-slot default, out of a hardware maximum of 8192, which is too
small for short traffic bursts.
Fix¶
Each node's nodes/<role>/<node>.yaml.j2 raises the ring on its X520 port
with an EthernetConfig document:
It applies without a reboot, but resizing the ring resets the NIC, so the
node briefly loses its network. Apply it one node at a time and wait for Ceph
to be healthy between nodes. To check the counters on a node, start a debug
pod with ethtool:
kubectl debug node/<node> -n default --profile=sysadmin \
--image=docker.io/nicolaka/netshoot:latest -- sleep 300
kubectl -n default exec <pod> -- ethtool -S enp1s0f0 | grep -E 'missed|dropped'
kubectl -n default exec <pod> -- ethtool -g enp1s0f0
Delete the debug pod by its exact name afterwards.
Seen¶
2026-10-28: k8s-02 dropped about 30,000 frames in one minute at 09:11 UTC and 23,000 at 12:11 UTC, which fired the alert twice. Since boot, the nodes had missed 2.6 million (k8s-01), 541,000 (k8s-02) and 51,000 (k8s-03) frames.