OSD NVMe Failure and Ceph Rebuild¶
Summary
2026-09-22 to 2026-10-01. The NVMe drive behind osd.2 on k8s-03 hung
three times in three days. Ceph stayed available on two replicas, with no
data loss, but a second-order RBD blocklist on another node left volumes
stuck for hours. The cluster was then rebuilt on Micron 7300 drives and
restored from backups, which exposed a cooling problem in k8s-03.
Timeline¶
- 2026-09-22 22:56 UTC. The SK hynix PC801 behind
osd.2stopped responding: I/O timeouts, a failed controller reset, then the kernel disabled the device. The PCIe device stayed visible intalosctl get pcidevices, which pointed at a hung controller rather than a dead or unseated card. Ceph went toHEALTH_WARNwith 33 PGs undersized. A power cycle (talosctl reboot -m powercycle) brought the drive back, and Rook reactivated the OSD on its existing data. - While degraded, k8s-02's kernel RBD client lost a watch and was
blocklisted. Every new
rbd mapon that node then failed withCannot send after transport endpoint shutdown, so pods and about 23 Kopiur backup jobs stayed stuck for hours after Ceph itself was back toHEALTH_OK. Removing the blocklist entry wasn't enough; rebooting k8s-02 was. - 2026-09-23 11:27 UTC and 2026-09-25 21:44 UTC. The same drive hung twice more. Each power cycle fixed it for a while, so a replacement drive was ordered.
- 2026-09-30. Instead of swapping one drive, all three nodes were reset
and the cluster rebuilt on Micron 7300 drives, with cephx moved to
aes256kkeys. Apps came back from Kopiur and CNPG Barman backups. - 2026-10-01. During the backfill, k8s-03's Micron reached 74 °C, close
to its 76 °C critical limit, so recovery was paused with
nobackfillandnorecover. k8s-03 was moved somewhere cooler, and recovery finished at 10:53 UTC with the drive peaking at 69 °C. - 2026-10-03. Rack cooling was improved: raised feet, open case bottoms and a 140 mm fan per node aimed at the NVMe drives and RAM. NVMe temperatures dropped by 18 to 23 °C.
Cause¶
A failing consumer NVMe drive. The rebuild then ran into a node chassis that couldn't cool an enterprise NVMe drive under sustained writes.
What changed¶
- Rook only uses Micron 7300 drives, selected by
/dev/disk/by-id(#2664, #2669). - cephx uses
aes256konly; the CSI driver needed a newer image for it (#2670). - Fixes found during the restore: the Dragonfly network policy blocked apps on port 6379, node-exporter lost port 9100 to the ephemeral port range (#2671), and Traefik on the NAS had no restart policy, so S3 stayed down after a NAS reboot and CNPG restores failed (#2672).
What to watch¶
- Pool health and a node's RBD session are separate. After a degraded
period, check
ceph osd blocklist lsand look for stuck volume mounts, even when Ceph reportsHEALTH_OK. - NVMe temperatures. k8s-03's Micron idles around 45 °C since the cooling changes, with a warning at 72 °C. A drift back up points at a fan.
- Resetting nodes while Ceph has no quorum hangs in
unmountPodMounts, because the kernel RBD client can't flush. A hard power-off gets past it.